NewClave Autohouse AD7 Prima 17L/22L

Simple, Practical and Reliable
The NewClave Autohouse AD7 delivers the most advanced utility for the autoclave. It is designed as simple, practical and reliable for your perfect sterilization.

  • One-click-ease to enable 4 pre-programmed sterilization cycles from the user-friendly LED control panel
  • 100% fully sterilization and drying performance with an automatic door opening mechanism.
  • Speedy 4 minutes sterilization cycle available for urgent usage
  • Extra sanitation assurance by two separated tanks – one for clean water and one for used
  • Hassle-free auto water drainage design
  • 7 safety mechanisms for utmost operation safety
  • High quality stainless steel chamber for longer reliability


  • Features
  • Specifications
  • Download
100% fully sterilization and excellent drying performance
The NewClave Autohouse ensures uncompromising sterilization under rigorous testing assurnce. Meanwhile, the AD7 provides excellent drying results within 30 minutes by the exclusive automatic door opening mechanism.

One-click-ease to enable 4 pre-programmed sterilization cycles from the user-friendly LED control panel

The NewClave Autohouse AD7 features an intuitive LED control panel with 4 pre-programmed cycles to meet all your sterilization needs. The LED control panel also offers quick and easy time and temperature monitoring.


 
Pre-programmed Cycle Sterilization Temperature Sterilization Time Instruction

1

Unwrapped

134℃

4 min.

Sterilization at 134℃ for 4 minutes, then drying for 15 minutes.

2

Pouches

134℃

18 min.

Sterilization at 134℃ for 18 minutes, then drying for 30 minutes.

3

Handpieces

134℃

6 min.

Sterilization at 134℃ for 6 minutes without drying.
*It is forbidden to put any volatile substances (such as anesthetics, ether and so on) in the device to sterilize; otherwise, the serious damage may occur.

4

Packs

121℃

30 min.

Sterilization at 121℃ for 30 minutes, then drying for 30 minutes.

 

  • Speedy 4 minutes sterilization cycle available (program 1)
    The program is designated for any urgent situation when you need instruments immediately. When selecting the emergency program, the instruments are sterilized only for 4 minutes at 134℃.

  • Extra sanitation assurance by two separated water tanks
    The NewClave Autohouse AD7 operates a single-use water system whereas most autoclaves use recycling water in a way which the dirty water largely undermines the sterilization performance. With two water tanks design, clean and used water is contained in different tanks respectively, and reliable sterilization is operated without any concern.

  • Hassle-free auto water drainage design
    The auto water drainage design conveniently avoids over-filling and saves your time for draining operation. All you have to do is to fill in water routinely. 

  • 7 safety mechanisms for utmost operation safety
    The NewClave Autohouse AD7 is designed with the world’s most comprehensive safety assurance by 7 mechanisms, delivering safe and reliable operation.

Temperature sensor

The units automatically switches off the heater when the temperature inside the chamber reaches 143℃.

Temperature switch

If the temperature of the outer fringe exceeds 149℃, this safety device will cut off the power supply automatically.

Safety valve

When the chamber pressure reaches 42 PSI (3 KG=289.2 Kpa), the valve will exhaust forcibly to make the pressure falling.

Dual door lock

The first door lock will unlock to open the door and speed up leaking the hot steam when drying. Meanwhile, the second door lock will still be locked to keep the door open slightly to prevent users from burning by hot steam.

Door lock indicator

The unit can be operated only after the signal of “Door ajar” lights off. This helps users make sure the door is properly locked before taking any

LED indicator

Door ajar: means the door is not properly locked. Users have to re-lock it properly.
Water low: if it lights on with “beep” sound in 6 minutes after selected program runs, it means water in the chamber is not enough for sterilization. Users have to re-load enough clean distilled or pure water into the reservoir until the arrow point of measure cup.
Error code: there are 4 error messages built-in.

Buzzer alert

There’s always a warning “beep” sound whenever there’s any error or before opening the door.

 

 


Specifications
- Classification : CLASS IIa
- Input voltage : 115V~ 0.8A (F1) / 115V~ 14A (F2、F3), 50/60Hz; 230V~ 0.4A (F1) / 230V~ 7A (F2、F3), 50/60Hz
- Fuse : F1A 250V (F1) / F20A 250V (F2、F3) (for 115V); F1A 250V (F1) / F10A 250V (F2、F3) (for 230V)
- Dimension : L60 x W39 x H44 (cm) / L70 x W40.5 x H46 (cm)
- Weight : 43 kg (net), 46 kg (gross) / 53 kg (net), 60 kg (gross)
- Chamber : D24 x L36 (cm) / D25 x L43 (cm)
- Capacity : 17 liter (or 6kg) / 22 liter (or 7.5kg)
- Tray : L30 x W17 x H2.2 (cm) / L42 x W19 x H2.2 (cm)
- Reservoir : 6,000 c.c / 6,000 c.c


Standard Accessories
- Water filter x 1
- Tray x 4
- Rack (for trays) x 1
- Tray handle with spanner (for rack picking & horizontal adjusting) x 1
- Water tube (2M w/ connector for manual draining) x 1
- Water tube (2.5M w/ connector for back draining outlet) x 1
- Water tray x 1